PFXGP4501TMD HMI Proface GP4000

Jual Proface PFXGP4501TMD

Jual HMI Proface PFXGP4501TMD

Jual HMI Proface PFXGP4501TMD

 

Jual HMI Proface PFXGP4501TMD | 

HMI Proface PFXGP4501TMD Standard product information :

Standard product information
Family
HMI
Series
GP4000 Series
Size
10″
Model
PFXGP4501TMD
Global Code
PFXGP4501TMD
Product Features
10″ DC Matrix
Repair Status
✔ (Maintenance service is available, able to be maintained.)

Display specifications HMI Proface PFXGP4501TMD

PFXGP4501TMD Display type
TFT Color LCD
PFXGP4501TMD Display size
10.4″
PFXGP4501TMD Resolution
640 x 480 pixels (VGA)
PFXGP4501TMD Effective display area
W211.2 x H158.4 mm [W8.31 x H6.24 in.]
PFXGP4501TMD Display colors
65,536 colors (No blink) / 16,384 colors (Blink)
Backlight
White LED (Not user replaceable. When replacement is required, contact your local distributor.)
Backlight service life
50,000 hrs. or more (each in continuous operation at 25 °C [77 °F] before backlight brightness decreases to 50%)
Brightness control
16 Levels (Adjusted with touch panel or software)
PFXGP4501TMD Touch panel type
Resistive Film (matrix)
PFXGP4501TMD Touch panel resolution
32 x 24 keys/screen
Touch panel lifetime
1,000,000 times or more
Language fonts
Japanese: 6,962 (JIS Standards 1 & 2) (including 607 non-kanji characters), ANK: 158 (Korean, Traditional Chinese, Simplified Chinese, Thai and Cyrillic can be added from the font setting of the screen editor. )
PFXGP4501TMD Character sizes
Standard font: 8 x 8, 8 x 16, 16 x 16 and 32 x 32 pixel fonts, Stroke font: 6 to 127 pixel fonts, Image font: 8 to 72 pixel fonts
Font sizes
Standard font: Width can be expanded up to 8 times. Height can be expanded up to 8 times.*1
8 x 8 dots
80 char. x 60 rows
8 x 16 dots
80 char. x 30 rows
16 x 16 dots
40 char. x 30 rows
32 x 32 dots
20 char. x 15 rows

Electrical specifications HMI Proface PFXGP4501TMD Yang Kami Jual

PFXGP4501TMD Rated input voltage
24 Vdc
Input voltage limits
19.2 to 28.8 Vdc
Allowable voltage drop
10 ms or less
PFXGP4501TMD Power consumption
17 W or less
In-rush current
30 A or less
PFXGP4501TMD Noise immunity
Noise Voltage : 1,000 Vp-p
Pulse Duration : 1 µs
Rise Time : 1 ns
(via noise simulator)
Voltage endurance
1,000 Vac, 20 mA for 1 minute (between power terminal and FG terminals)
Insulation resistance
500 Vdc, 10 MΩ or more (between power terminal and FG terminals)

International safety standards HMI Proface PFXGP4501TMD Yang Kami Jual

Surrounding air temperature
0 to 55 °C [32 to 131 °F]
PFXGP4501TMD Storage temperature
-20 to +60 °C [-4 to 140 °F]
Ambient humidity
10 to 90 % RH (Wet bulb temperature: 39 °C [102.2 °F] max. – no condensation)
Storage humidity
10 to 90 % RH (Wet bulb temperature: 39 °C [102.2 °F] max. – no condensation)
Dust
0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive levels)
Pollution degree
For use in Pollution Degree 2 environment
Corrosive gases
Free of corrosive gases
Air pressure (altitude range)
800 to 1,114 hPa (2,000 m [6,561 ft.] above sea level or less)
Vibration resistance
IEC/EN 61131-2 compliant
5 to 9 Hz single amplitude 3.5 mm [0.14 in.]
9 to 150 Hz fixed acceleration: 9.8 m/s2
X, Y, Z directions for 10 cycles (approx. 100 min.)
Concussion resistance
IEC/EN 61131-2 compliant 147 m/s2, X, Y, Z directions for 3 times
Electrostatic discharge immunity
Contact Discharge Method: 6 kV (IEC/EN61000-4-2 Level 3)

Memory HMI Proface PFXGP4501TMD

Application memory
When using GP-Pro EX:
– Media: FLASH EPROM
– Screen Area: 32MB *Use the screen area when the user font area’s capacity is exceeded – for example, when an image font or a picture font is used.
– User Font Area: 8MB
– Logic Program Area: 132KB (Equivalent to 15,000 steps) *Up to 60,000 steps can be converted in software. However, this reduces application memory capacity (for screen data) by 1 MB.
– Free Space: NoneRemovable System: No
Backup memory
When using GP-Pro EX:
– Screen Area: SRAM 320KB
– Variable Area: SRAM 64KBBattery: Replaceable battery / Primary battery for clock data backup
Clock accuracy
±65 sec./month (deviation at room temperature and power is OFF)

Depending on the operating temperature and age of unit, the clock can deviate from -380 to +90 sec./month. For systems where this level of deviation is a problem, the user should monitor and make adjustments when required.

Interface specifications HMI Proface PFXGP4501TMD

Serial (COM1)
Asynchronous Transmission: RS-232C, Data Length: 7 or 8 bits, Stop Bit: 1 or 2 bits, Parity: None, Even or Odd, Data Transmission Speed: 2,400 to 115,200 bps, Connector: D-Sub 9 (plug)
Serial (COM2)
Asynchronous Transmission: RS-422 / 485, Data Length: 7 or 8 bits, Stop Bit: 1 or 2 bits, Parity: None, Even or Odd, Data Transmission Speed: 2,400 to 115,200 bps, 187,500 bps (MPI), Connector: D-Sub 9 pin (plug)
USB (Type A)
Conforms to USB 2.0 (Type A) x 1
PFXGP4501TMD Power supply voltage: 5 Vdc ±5 %
Output Current: 500 mA or less
Communication distance: 5 m [16.4 ft.] or less
USB (mini-B)
Conforms to USB 2.0 (mini-B) x 1, Communication Distance: 5 m [16.4 ft] or less
Ethernet
IEEE802.3i / IEEE802.3u, 10BASE-T / 100BASE-TX, Connector: Modular jack (RJ-45) x 1
SD card
SD Card Slot x 1

Structural specifications HMI Proface PFXGP4501TMD

PFXGP4501TMD Grounding
Functional grounding: Grounding resistance of 100 Ω, 2mm2 (AWG 14) or thicker wire, or your country’s applicable standard. (Same for FG and SG terminals)
Cooling method
Natural air circulation
PFXGP4501TMD Structure
IP65f NEMA #250 TYPE 4X/13 (on the front panel when properly installed in an enclosure)*3
External dimensions
W272.5 x H214.5 x D57 mm [W10.73 x H8.45 x D2.25 in.]
Panel cut-out dimensions
W259 x H201 mm [W10.19 x H7.91 in.]
Panel thickness area: 1.6 to 5 mm [0.06 to 0.2 in.]*4
Weight
2 kg [4.41 lb] or less

The front face of this product, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification.

For dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.]. Even if the installation wall thickness is within the recommended range for the “Panel Cut Dimensions”, depending on wall’s material, size, and installation location of GP unit and other devices, the installation wall could warp. To prevent warping, the installation surface may need to be strengthened.