1) Limit values, reverse-polarity protected Operation in short-circuit protected network: max. 8 A, class 2.
2) 15 V … 30 V when using the analog voltage output.
3) Without load.
Performance
Operating range, limiting range
350 mm … 3,400 mm, 5,000 mm
Target
Natural objects
Resolution
≥ 0.18 mm
Repeatability
± 0.15 % 1)
Accuracy
± 1 % 2)3)
Temperature compensation
✔
Response time
180 ms 4)
Switching frequency
4 Hz
Output time
43 ms
Ultrasonic frequency (typical)
120 kHz
Detection area (typical)
See diagrams
Additional function
Adjustable operating modes: Switching point (DtO) / Switching window/Background (ObSB), teach-in of digital output, set levels of digital outputs, invertable digital output, set on delay digital output, teach-in of analog output, scaling of analog outputs, Invertable analog output, automatic selection of analog current or voltage output, synchronization of up to 50 sensors, multiplexing: no cross talk of up to 50 sensors, adjustable measurement filters: Measured value filters/Filter strength/Foreground suppression/Detection area/Sensitivity and sound beam, reset to factory default
1) In relation to the current measured value, minimum value ≥ resolution.
2) Referring to current measurement value.
3) Temperature compensation can be switched off, without temperature compensation: 0.17 % / K.
4) Subsequent smoothing of the analog output, depending on the application, may increase the response time by up to 200 %.
Interfaces
Digital output
Number
1 1)
Type
PNP
Maximum output current IA
≤ 200 mA
Analog output
Number
1
Type
Current output / voltage output
Function
Automatic selection of analog current or voltage output dependent on load
Current
4 mA … 20 mA, ≤ 500 Ω 2)
Voltage
0 V … 10 V, ≥ 100,000 Ω
Resolution
12 bit
Multifunctional input (MF)
1 x MF
Hysteresis
50 mm
1) PNP: HIGH = VS – (< 2 V) / LOW = 0 V.
2) For 4 mA … 20 mA and Vs ≤ 20 V max. load ≤ 100 Ω.