PFXGP4601TMD Proface HMI

Jual Proface PFXGP4501TMD

Jual HMI Proface PFXGP4601TMD

Proface HMI PFXGP4601TMD

 

Jual Proface HMI PFXGP4601TMD | 

Proface HMI PFXGP4601TMD Standard Specification : 

Standard product information
Family
HMI
Series
GP4000 Series
Size
12″
Model
PFXGP4601TMA
Global Code
PFXGP4601TMA
Product Features
12″ AC Matrix
Repair Status
✔ (Maintenance service is available, able to be maintained.)

Display specifications Proface HMI PFXGP4601TMD Yang Kami Jual

PFXGP4601TMD Electrical specifications
Rated input voltage
100 to 240 Vac
PFXGP4601TMD Input voltage limits
85 to 264 Vac
PFXGP4601TMD Rated frequency
50 / 60 Hz
Rated frequency range
47 to 63 Hz
Allowable voltage drop
1 cycle or less (Voltage drop interval must be 1 second or more.)
Power consumption
100 Vac: 44 VA or less, 240 Vac: 58 VA or less
In-rush current
30 A or less
PFXGP4601TMD Noise immunity
Noise Voltage : 1,500 Vp-p
Pulse Duration : 1 µs
Rise Time : 1 ns
(via noise simulator)
Voltage endurance
1,500 Vac, 20 mA for 1 minute (between power terminal and FG terminals)
Insulation resistance
500 Vdc, 10 MΩ or more (between power terminal and FG terminals)

Environmental specifications Proface HMI PFXGP4601TMD

International safety standards
Surrounding air temperature
0 to 55 °C [32 to 131 °F]
Storage temperature
-20 to +60 °C [-4 to 140 °F]
PFXGP4601TMD Ambient humidity
10 to 90 % RH (Wet bulb temperature: 39 °C [102.2 °F] max. – no condensation)
Storage humidity
10 to 90 % RH (Wet bulb temperature: 39 °C [102.2 °F] max. – no condensation)
Dust
0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive levels)
Pollution degree
For use in Pollution Degree 2 environment
Corrosive gases
Free of corrosive gases
Air pressure (altitude range)
800 to 1,114 hPa (2,000 m [6,561 ft.] above sea level or less)
Vibration resistance
IEC/EN 61131-2 compliant
5 to 9 Hz single amplitude 3.5 mm [0.14 in.]
9 to 150 Hz fixed acceleration: 9.8 m/s2
X, Y, Z directions for 10 cycles (approx. 100 min.)
Concussion resistance
IEC/EN 61131-2 compliant 147 m/s2, X, Y, Z directions for 3 times
Electrostatic discharge immunity
Contact Discharge Method: 6 kV (IEC/EN61000-4-2 Level 3)

Proface HMI PFXGP4601TMD Memory

PFXGP4601TMD Application memory
When using GP-Pro EX:
– Media: FLASH EPROM
– Screen Area: 32MB *Use the screen area when the user font area’s capacity is exceeded – for example, when an image font or a picture font is used.
– User Font Area: 8MB
– Logic Program Area: 132KB (Equivalent to 15,000 steps) *Up to 60,000 steps can be converted in software. However, this reduces application memory capacity (for screen data) by 1 MB.
– Free Space: NoneRemovable System: No
Backup memory
When using GP-Pro EX:
– Screen Area: SRAM 320KB
– Variable Area: SRAM 64KBBattery: Replaceable battery / Primary battery for clock data backup
Clock accuracy
±65 sec./month (deviation at room temperature and power is OFF)

2*) Depending on the operating temperature and age of unit, the clock can deviate from -380 to +90 sec./month. For systems where this level of deviation is a problem, the user should monitor and make adjustments when required.

Interface specifications Proface HMI PFXGP4601TMD

PFXGP4601TMD Serial (COM1)
Asynchronous Transmission: RS-232C, Data Length: 7 or 8 bits, Stop Bit: 1 or 2 bits, Parity: None, Even or Odd, Data Transmission Speed: 2,400 to 115,200 bps, Connector: D-Sub 9 (plug)
Serial (COM2)
Asynchronous Transmission: RS-422 / 485, Data Length: 7 or 8 bits, Stop Bit: 1 or 2 bits, Parity: None, Even or Odd, Data Transmission Speed: 2,400 to 115,200 bps, 187,500 bps (MPI), Connector: D-Sub 9 pin (plug)
USB (Type A)
Conforms to USB 2.0 (Type A) x 1
PFXGP4601TMD Power supply voltage: 5 Vdc ±5 %
PFXGP4601TMD Output Current: 500 mA or less
Communication distance: 5 m [16.4 ft.] or less
USB (mini-B)
Conforms to USB 2.0 (mini-B) x 1, Communication Distance: 5 m [16.4 ft] or less
Ethernet
IEEE802.3i / IEEE802.3u, 10BASE-T / 100BASE-TX, Connector: Modular jack (RJ-45) x 1
SD card
SD Card Slot x 1

Structural specifications Proface HMI PFXGP4601TMD

PFXGP4601TMD Structural specifications
Grounding
Functional grounding: Grounding resistance of 100 Ω, 2mm2 (AWG 14) or thicker wire, or your country’s applicable standard. (Same for FG and SG terminals)
Cooling method
Natural air circulation
PFXGP4601TMD Structure
IP65f NEMA #250 TYPE 4X/13 (on the front panel when properly installed in an enclosure)
External dimensions
W315 x H241 x D56 mm [W12.4 x H9.49 x D2.20 in.]
Panel cut-out dimensions
W301.5 x H227.5 mm [W11.87 x H8.96 in.]
Panel thickness area: 1.6 to 5 mm [0.06 to 0.2 in.]
Weight
2.5 kg [5.5 lb] or less

the front face of this product, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification.

For dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.]. Even if the installation wall thickness is within the recommended range for the “Panel Cut Dimensions”, depending on wall’s material, size, and installation location of GP unit and other devices, the installation wall could warp. To prevent warping, the installation surface may need to be strengthened.