PFXGP4301TAD Proface HMI Touch Screen

Jual Proface PFXGP4301TAD HMI Touch Screen

Proface PFXGP4301TAD

 

Jual Proface PFXGP4301TAD HMI Touch Screen | 

HMI Proface PFXGP4301TAD Standard information

Standard product information
Family
HMI
Series
GP4000 Series
Size
5″
Model
PFXGP4301TAD
Global Code
PFXGP4301TAD
Product Features
5″ DC Analog
Repair Status
✔ (Maintenance service is available, able to be maintained.)

HMI Proface PFXGP4301TAD Display type

TFT Color LCD
PFXGP4301TAD Display size
5.7″
PFXGP4301TAD Resolution
320 x 240 pixels (QVGA)
PFXGP4301TAD Effective display area
W115.2 x H86.4 mm [W4.54 x H3.40 in.]
PFXGP4301TAD Display colors
65,536 colors (No blink) / 16,384 colors (Blink)
PFXGP4301TAD Backlight
White LED (Not user replaceable. When replacement is required, contact your local distributor.)
Backlight service life
50,000 hrs. or more (each in continuous operation at 25 °C [77 °F] before backlight brightness decreases to 50%)
Brightness control
16 Levels (Adjusted with touch panel or software)
PFXGP4301TAD Touch panel type
Resistive Film (analog)
PFXGP4301TAD Touch panel resolution
1,024 x 1,024
PFXGP4301TAD Touch panel lifetime
1,000,000 times or more
Language fonts
Japanese: 6,962 (JIS Standards 1 & 2) (including 607 non-kanji characters), ANK: 158 (Korean, Traditional Chinese, Simplified Chinese, Thai and Cyrillic can be added from the font setting of the screen editor. )
PFXGP4301TAD Character sizes
Standard font: 8 x 8, 8 x 16, 16 x 16 and 32 x 32 pixel fonts, Stroke font: 6 to 127 pixel fonts, Image font: 8 to 72 pixel fonts
PFXGP4301TAD Font sizes
Standard font: Width can be expanded up to 8 times. Height can be expanded up to 8 times.*1
8 x 8 dots
40 char. x 30 rows
8 x 16 dots
40 char. x 15 rows
16 x 16 dots
20 char. x 15 rows
32 x 32 dots
10 char. x 7 rows

1*)Other font sizes can be set up with the Editor software.

HMI Proface PFXGP4301TAD Electrical specifications

PFXGP4301TAD Rated input voltage
24 Vdc
PFXGP4301TAD Input voltage limits
19.2 to 28.8 Vdc
Allowable voltage drop
5 ms or less
PFXGP4301TAD Power consumption
10.5 W or less
In-rush current
30 A or less
PFXGP4301TAD Noise immunity
Noise Voltage : 1,000 Vp-p
Pulse Duration : 1 µs
Rise Time : 1 ns
(via noise simulator)
Voltage endurance
1,000 Vac, 20 mA for 1 minute (between power terminal and FG terminals)
Insulation resistance
500 Vdc, 10 MΩ or more (between power terminal and FG terminals)

HMI Proface PFXGP4301TAD Environmental specifications

International safety standards
Surrounding air temperature
0 to 55 °C [32 to 131 °F]
Storage temperature
-20 to +60 °C [-4 to 140 °F]
Ambient humidity
10 to 90 % RH (Wet bulb temperature: 39 °C [102.2 °F] max. – no condensation)
Storage humidity
10 to 90 % RH (Wet bulb temperature: 39 °C [102.2 °F] max. – no condensation)
Dust
0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive levels)
Pollution degree
For use in Pollution Degree 2 environment
Corrosive gases
Free of corrosive gases
Air pressure (altitude range)
800 to 1,114 hPa (2,000 m [6,561 ft.] above sea level or less)
PFXGP4301TAD Vibration resistance
IEC/EN 61131-2 compliant
5 to 9 Hz single amplitude 3.5 mm [0.14 in.]
9 to 150 Hz fixed acceleration: 9.8 m/s2
X, Y, Z directions for 10 cycles (approx. 100 min.)
PFXGP4301TAD Concussion resistance
IEC/EN 61131-2 compliant 147 m/s2, X, Y, Z directions for 3 times
Electrostatic discharge immunity
Contact Discharge Method: 6 kV (IEC/EN61000-4-2 Level 3)

HMI Proface PFXGP4301TAD Memory

PFXGP4301TAD Application memory
When using GP-Pro EX:
– Media: FLASH EPROM
– Screen Area: 16MB *Use the screen area when the user font area’s capacity is exceeded – for example, when an image font or a picture font is used.
– User Font Area: 8MB
– Logic Program Area: 132KB (Equivalent to 15,000 steps) *Up to 60,000 steps can be converted in software. However, this reduces application memory capacity (for screen data) by 1 MB.
– Free Space: NoneRemovable System: No
Backup memory
When using GP-Pro EX:
– Screen Area: SRAM 320KB
– Variable Area: SRAM 64KBBattery: Replaceable battery / Primary battery for clock data backup
Clock accuracy
±65 sec./month (deviation at room temperature and power is OFF)*2

2*)Depending on the operating temperature and age of unit, the clock can deviate from -380 to +90 sec./month. For systems where this level of deviation is a problem, the user should monitor and make adjustments when required.

HMI Proface PFXGP4301TAD Interface specifications

Serial (COM1)
Asynchronous Transmission: RS-232C, Data Length: 7 or 8 bits, Stop Bit: 1 or 2 bits, Parity: None, Even or Odd, Data Transmission Speed: 2,400 to 115,200 bps, Connector: D-Sub 9 (plug)
Serial (COM2)
Asynchronous Transmission: RS-422 / 485, Data Length: 7 or 8 bits, Stop Bit: 1 or 2 bits, Parity: None, Even or Odd, Data Transmission Speed: 2,400 to 115,200 bps, 187,500 bps (MPI), Connector: D-Sub 9 pin (plug)
USB (Type A)
Conforms to USB 2.0 (Type A) x 1
PFXGP4301TAD Power supply voltage: 5 Vdc ±5 %
Output Current: 500 mA or less
Communication distance: 5 m [16.4 ft.] or less
USB (mini-B)
Conforms to USB 2.0 (mini-B) x 1, Communication Distance: 5 m [16.4 ft] or less
Ethernet
IEEE802.3i / IEEE802.3u, 10BASE-T / 100BASE-TX, Connector: Modular jack (RJ-45) x 1
SD card
SD Card Slot x 1

HMI Proface PFXGP4301TAD Structural specifications

PFXGP4301TAD Grounding
Functional grounding: Grounding resistance of 100 Ω, 2mm2 (AWG 14) or thicker wire, or your country’s applicable standard. (Same for FG and SG terminals)
Cooling method
Natural air circulation
PFXGP4301TAD Structure
IP65f NEMA #250 TYPE 4X/13 (on the front panel when properly installed in an enclosure)*3
PFXGP4301TAD External dimensions
W169.5 x H137 x D59.5 mm [W6.67 x H5.39 x D2.34 in.]
Panel cut-out dimensions
W156 x H123.5 mm [W6.14 x H4.86 in.]
Panel thickness area: 1.6 to 5 mm [0.06 to 0.2 in.]*4
Weight
0.8 kg [1.76 lb] or less

3*)The front face of the unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification. Even though the unit’s level of resistance is equivalent to these standards, oils that should have no effect on the unit can possibly harm the unit.

This can occur in areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to adhere to the unit for long periods of time. If the unit’s front face protection sheet becomes peeled off, these conditions can lead to the ingress of oil into the unit and separate protection measures are suggested. Also, if non-approved oils are present, it may cause deformation or corrosion of the front panel’s plastic cover. Therefore, prior to installing the unit, be sure to confirm the type of conditions that will be present in the unit’s operating environment. If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from the panel, the original level of the protection cannot be guaranteed. To maintain the original protection level, be sure to replace the installation gasket regularly.

PFXGP4301TAD Dimensional

4*)For dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.]. Even if the installation wall thickness is within the recommended range for the “Panel Cut Dimensions”, depending on wall’s material, size, and installation location of GP unit and other devices, the installation wall could warp. To prevent warping, the installation surface may need to be strengthened.

HMI Proface Lainnya