IFM SD6100 Flow rate meter

Jual IFM SD6100 Flow rate meter for gases

IFM SD6100

IFM SD6100 Flow rate meter for gases SDR12DGXFPKG/US-100

IFM SD6100 Flow rate meter for gases Specification : 

  • Precise measurement of flow, consumption and medium temperature
  • High accuracy, repeatability and measurement dynamics
  • For detecting argon (Ar), carbon dioxide (CO2), nitrogen (N2)
  • With switching output, analogue output and pulse output
  • Clearly visible 4-digit LED display

IFM SD6100 Product characteristics

Number of inputs and outputs digital outputs: 2; analogue outputs: 1
Process connection threaded connection R 1/2 DN15

IFM SD6100 Temperature monitoring

Measuring range [°C] 0…60

IFM SD6100 Application

Application for industrial applications
Media Argon (Ar); carbon dioxide (CO2); nitrogen (N2)
Medium temperature [°C] 0…60
Pressure rating [bar] 16
Pressure rating [Mpa] 1.6

IFM SD6100 Electrical data

Operating voltage [V] 18…30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA] < 100
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 1

IFM SD6100 Inputs / outputs

Number of inputs and outputs digital outputs: 2; analogue outputs: 1

IFM SD6100 Outputs

Total number of outputs 2
Output signal switching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical design PNP
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 250; (per output)
Number of analogue outputs 1
Analogue current output [mA] 4…20; (scalable)
Max. load [Ω] 500
Pulse output consumed quantity meter
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes

IFM SD6100 Measuring/setting range

Low flow cut-off LFC [m³/h] < 1.3
Measuring dynamics 1:300
Ar
Measuring range [m³/h] 0.4…122
Display range [m³/h] 0…146.4
Resolution [m³/h] 0.1
Set point SP [m³/h] 1.1…122
Reset point rP [m³/h] 0.6…121.5
Analogue start point ASP [m³/h] 0…97.6
Analogue end point AEP [m³/h] 24.4…122
In steps of [m³/h] 0.1
CO2
Measuring range [m³/h] 0.2…74.7
Display range [m³/h] 0…89.7
Resolution [m³/h] 0.1
Set point SP [m³/h] 0.7…74.7
Reset point rP [m³/h] 0.4…74.4
Analogue start point ASP [m³/h] 0…59.8
Analogue end point AEP [m³/h] 14.9…74.7
In steps of [m³/h] 0.1

IFM SD6100  Volumetric flow quantity monitoring

Pulse value 0.001…1 000 000 m³
In steps of 0.001…1000 m³
Pulse length [s] 0,012…2
N2
Measuring range [m³/h] 0.2…75
Display range [m³/h] 0…90
Resolution [m³/h] 0.1
Set point SP [m³/h] 0.7…75
Reset point rP [m³/h] 0.4…74.7
Analogue start point ASP [m³/h] 0…60
Analogue end point AEP [m³/h] 15…75
In steps of [m³/h] 0.1

IFM SD6100 Temperature monitoring

Measuring range [°C] 0…60
Display range [°C] -12…72
Resolution [°C] 0.2
Set point SP [°C] 0.4…60
Reset point rP [°C] 0…59.8
Analogue start point [°C] 0…48
Analogue end point [°C] 12…60
In steps of [°C] 0.2

IFM SD6100 Accuracy / deviations

Flow monitoring

Repeatability [% of the measured value] ± 1,5
Accuracy (in the measuring range) ± (6 % MW + 0,6 % MEW); (conditions: installation to DIN ISO 2533; installation in pipes: DN15)

IFM SD6100 Temperature monitoring

Accuracy [K] ± 2; (medium flow in the limit area of the flow measurement range)
Response times

IFM SD6100 Flow monitoring

Response time [s] 0.1; (dAP = 0)
Damping for the switching output dAP in steps [s] 0 – 0,2 – 0,4 – 0,6 – 0,8 – 1
Software / programming
Parameter setting options Flow monitoring; quantity meter; Preset counter; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; medium selection

IFM SD6100 Interfaces

Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
IO-Link device ID 265 d / 00 01 09 h
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode yes
Required master port type A
Process data analogue 3
Process data binary 2
Min. process cycle time [ms] 4.1

Operating conditions

Ambient temperature [°C] 0…60
Storage temperature [°C] -20…85
Max. relative air humidity [%] 90
Protection IP 65
Tests / approvals
EMC
EN 61000-4-2 ESD 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated 10 V/m
EN 61000-4-4 Burst 2 kV
EN 61000-4-6 HF conducted 10 V
Vibration resistance
DIN IEC 68-2-6 5 g (55…2000 Hz)
MTTF [years] 227
Pressure Equipment Directive Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request

IFM SD6100 Mechanical data

Weight [g] 963.5
Materials PBT-GF20; PC; PC; stainless steel (1.4301 / 304); FKM
Materials (wetted parts) stainless steel (1.4301 / 304); ceramics glass passivated; PEEK; polyester; FKM; aluminium anodised
Tightening torque [Nm] 50
Process connection threaded connection R 1/2 DN15

Displays / operating elements

Display
Display unit 4 x LED, green (Nl/min, Nm³/h, Nm³, °C)
function display 1 x LED, yellow
switching status 2 x LED, yellow
measured values alphanumeric display, 4-digit
programming alphanumeric display, 4-digit
Display unit Nl/min; Nm³/h; Nm³; °C
Remarks
Remarks
MW = measured value
MEW = Final value of the measuring range
Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533.
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12

Type IFM SD Series lainnya

SD8500
SD2500
SD9500
SD5500
SD6500
SD8000
SD6000
SD0523
SD6050
SD2000
SD8600
SD6600
SD5600
SD6100
SD5000
SD9000
SD5100
SD8100
SD6101
SDG070
SDG207
SD6001
SDG107
SDG087
SD8001
SDG157
SDG152
SDG082
SDG200
SDG201
SDG080
SDG100
SDG150
SD2001
SDG102
SD1540
SD2501
SD8501
SD6601
SD8601
SD5800
SD6800

Instrument lainnya

Transmitter IFM Lainnya

Datasheet Katalog IFM SD6100