IFM SD6100 Product characteristics
|
Number of inputs and outputs |
digital outputs: 2; analogue outputs: 1 |
Process connection |
threaded connection R 1/2 DN15 |
IFM SD6100 Temperature monitoring
|
Measuring range [°C] |
0…60 |
IFM SD6100 Application
|
Application |
for industrial applications |
Media |
Argon (Ar); carbon dioxide (CO2); nitrogen (N2) |
Medium temperature [°C] |
0…60 |
Pressure rating [bar] |
16 |
Pressure rating [Mpa] |
1.6 |
IFM SD6100 Electrical data
|
Operating voltage [V] |
18…30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA] |
< 100 |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
1 |
IFM SD6100 Inputs / outputs
|
Number of inputs and outputs |
digital outputs: 2; analogue outputs: 1 |
IFM SD6100 Outputs
|
Total number of outputs |
2 |
Output signal |
switching signal; analogue signal; pulse signal; IO-Link; (configurable) |
Electrical design |
PNP |
Number of digital outputs |
2 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] |
2 |
Permanent current rating of switching output DC [mA] |
250; (per output) |
Number of analogue outputs |
1 |
Analogue current output [mA] |
4…20; (scalable) |
Max. load [Ω] |
500 |
Pulse output |
consumed quantity meter |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
IFM SD6100 Measuring/setting range
|
Low flow cut-off LFC [m³/h] |
< 1.3 |
Measuring dynamics |
1:300 |
Ar |
Measuring range [m³/h] |
0.4…122 |
Display range [m³/h] |
0…146.4 |
Resolution [m³/h] |
0.1 |
Set point SP [m³/h] |
1.1…122 |
Reset point rP [m³/h] |
0.6…121.5 |
Analogue start point ASP [m³/h] |
0…97.6 |
Analogue end point AEP [m³/h] |
24.4…122 |
In steps of [m³/h] |
0.1 |
CO2 |
Measuring range [m³/h] |
0.2…74.7 |
Display range [m³/h] |
0…89.7 |
Resolution [m³/h] |
0.1 |
Set point SP [m³/h] |
0.7…74.7 |
Reset point rP [m³/h] |
0.4…74.4 |
Analogue start point ASP [m³/h] |
0…59.8 |
Analogue end point AEP [m³/h] |
14.9…74.7 |
In steps of [m³/h] |
0.1 |
IFM SD6100 Volumetric flow quantity monitoring
|
Pulse value |
0.001…1 000 000 m³ |
In steps of |
0.001…1000 m³ |
Pulse length [s] |
0,012…2 |
N2 |
Measuring range [m³/h] |
0.2…75 |
Display range [m³/h] |
0…90 |
Resolution [m³/h] |
0.1 |
Set point SP [m³/h] |
0.7…75 |
Reset point rP [m³/h] |
0.4…74.7 |
Analogue start point ASP [m³/h] |
0…60 |
Analogue end point AEP [m³/h] |
15…75 |
In steps of [m³/h] |
0.1 |
IFM SD6100 Temperature monitoring
|
Measuring range [°C] |
0…60 |
Display range [°C] |
-12…72 |
Resolution [°C] |
0.2 |
Set point SP [°C] |
0.4…60 |
Reset point rP [°C] |
0…59.8 |
Analogue start point [°C] |
0…48 |
Analogue end point [°C] |
12…60 |
In steps of [°C] |
0.2 |
IFM SD6100 Accuracy / deviations
|
Flow monitoring
|
Repeatability [% of the measured value] |
± 1,5 |
Accuracy (in the measuring range) |
± (6 % MW + 0,6 % MEW); (conditions: installation to DIN ISO 2533; installation in pipes: DN15) |
IFM SD6100 Temperature monitoring
|
Accuracy [K] |
± 2; (medium flow in the limit area of the flow measurement range) |
Response times |
IFM SD6100 Flow monitoring
|
Response time [s] |
0.1; (dAP = 0) |
Damping for the switching output dAP in steps [s] |
0 – 0,2 – 0,4 – 0,6 – 0,8 – 1 |
Software / programming |
Parameter setting options |
Flow monitoring; quantity meter; Preset counter; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; medium selection |
IFM SD6100 Interfaces
|
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 |
IO-Link device ID |
265 d / 00 01 09 h |
Profiles |
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode |
yes |
Required master port type |
A |
Process data analogue |
3 |
Process data binary |
2 |
Min. process cycle time [ms] |
4.1 |
Operating conditions
|
Ambient temperature [°C] |
0…60 |
Storage temperature [°C] |
-20…85 |
Max. relative air humidity [%] |
90 |
Protection |
IP 65 |
Tests / approvals |
EMC |
EN 61000-4-2 ESD |
4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated |
10 V/m |
EN 61000-4-4 Burst |
2 kV |
EN 61000-4-6 HF conducted |
10 V |
|
Vibration resistance |
DIN IEC 68-2-6 |
5 g (55…2000 Hz) |
|
MTTF [years] |
227 |
Pressure Equipment Directive |
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
IFM SD6100 Mechanical data
|
Weight [g] |
963.5 |
Materials |
PBT-GF20; PC; PC; stainless steel (1.4301 / 304); FKM |
Materials (wetted parts) |
stainless steel (1.4301 / 304); ceramics glass passivated; PEEK; polyester; FKM; aluminium anodised |
Tightening torque [Nm] |
50 |
Process connection |
threaded connection R 1/2 DN15 |
Displays / operating elements
|
Display |
Display unit |
4 x LED, green (Nl/min, Nm³/h, Nm³, °C) |
function display |
1 x LED, yellow |
switching status |
2 x LED, yellow |
measured values |
alphanumeric display, 4-digit |
programming |
alphanumeric display, 4-digit |
|
Display unit |
Nl/min; Nm³/h; Nm³; °C |
Remarks |
Remarks |
MW = measured value |
MEW = Final value of the measuring range |
Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533. |
|
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x M12 |