IFM SM8100 Magnetic-inductive flow meter

IFM-SM8100

IFM SM8100 Magnetic-inductive flow meter

Jual IFM SM8100 Magnetic-inductive flow meter |

  • With volumetric flow quantity, total quantity and temperature indication
  • High accuracy, repeatability and measurement dynamics
  • For use in conductive media from 20 μS/cm
  • With switching output, analogue output and pulse output
  • Clearly visible LED display

 

IFM SM8100 Product characteristics
Number of inputs and outputs digital outputs: 2 and analogue outputs: 1
Process connection threaded connection G 1 DN25 flat seal
Temperature monitoring
Measuring range [°C] -20…80
IFM SM8100 Application
Special feature Gold-plated contacts
Application totaliser function; for industrial applications
Installation connection to pipe by means of an adapter
Media conductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C] -10…70
Pressure rating [bar] 16
Pressure rating [Mpa] 1.6
MAWP (for applications according to CRN) [bar] 11.2
IFM SM8100 Electrical data
Operating voltage [V] 18…30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA] 95; (24 V)
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 5
IFM SM8100 Inputs / outputs
 inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputs counter reset
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 200
Number of analogue outputs 1
Analogue current output [mA] 4…20; (scalable)
Max. load [Ω] 500
Analogue voltage output [V] 0…10; (scalable)
Min. load resistance [Ω] 2000
Pulse output flow rate meter
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes

IFM SM8100 Measuring/setting range

Measuring range
0.2…100 l/min 0.01…6 m³/h
Display range
-120…120 l/min -7.2…7.2 m³/h
Resolution
0.1 l/min 0.005 m³/h
Set point SP
0.7…100 l/min 0.04…6 m³/h
Reset point rP
0.2…99.5 l/min 0.01…5.97 m³/h
Analogue start point ASP
0…80 l/min 0…4.8 m³/h
Analogue end point AEP
20…100 l/min 1.2…6 m³/h
In steps of
0.1 l/min 0.005 m³/h
Volumetric flow quantity monitoring
Pulse value 0.00001…100 000 m³
Pulse length [s] 0,0025…2
Temperature monitoring
Measuring range [°C] -20…80
Resolution [°C] 0.2
Set point SP [°C] -19.2…80
Reset point rP [°C] -19.6…79.6
Analogue start point [°C] -20…60
Analogue end point [°C] 0…80
In steps of [°C] 0.2
Accuracy / deviations

Flow monitoring

Accuracy (in the measuring range) ± (0,8 % MW + 0,5 % MEW)
Repeatability ± 0,2% MEW
Temperature monitoring
Accuracy [K] ± 2,5 (Q > 5 l/min)
Response times
Flow monitoring
Response time [s] 0.15; (dAP = 0, T19)
Delay time programmable dS, dr [s] 0…50
Damping for the switching output dAP [s] 0…5
Temperature monitoring
Dynamic response T05 / T09 [s] T09 = 20 (Q > 5 l/min)
Software / programming
Parameter setting options Flow monitoring; quantity meter; Preset counter and Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit

IFM SM8100 Interfaces

Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
IO-Link device ID 575 / 00 02 3f
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode yes
Required master port type A
Process data analogue 3
Process data binary 2
Min. process cycle time [ms] 5
IFM SM8100Operating conditions
Ambient temperature [°C] -10…60
Storage temperature [°C] -25…80
Protection IP 67
IFM SM8100 Tests and approvals
EMC
DIN EN 60947-5-9
Shock resistance
DIN IEC 68-2-27 20 g (11 ms)
Vibration resistance
DIN IEC 68-2-6 5 g (10…2000 Hz)
MTTF [years] 145
Pressure Equipment Directive Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request

IFM SM8100 Mechanical data

Weight [g] 639.5
Materials stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Materials (wetted parts) stainless steel (1.4404 / 316L); PEEK; EPDM
Process connection threaded connection G 1 DN25 flat seal
IFM SM8100 Displays and operating elements
Display
Display unit 6 x LED, green (l/min, m³/h, l, m³, 10³, °C)
switching status 2 x LED, yellow
measured values alphanumeric display, 4-digit
programming alphanumeric display, 4-digit
Remarks
Remarks
MW = measured value
MEW = Final value of the measuring range
Pack quantity 1 pcs.
IFM SM8100 Electrical connection
Connection Connector: 1 x M12; Contacts: gold-plated

Type Flow Meter IFM SM8100 Lainnya :

SM6000
SM8000
SM6004
SM7000
SM9000
SM6100
SM2000
SM8004
SM8100
SM9004
SM2001
SM9001
SM7004
SM2004
SM9100
SM8001
SM6001
SM4000
SM0510
SM2100
SM7100
SM0510
SM2100
SM7100
SM6604
SM2601
SM9601

SM8601
SM8050
SM6050
SM2604
SM9604
SM7601
SM7604
SM6400
SM4100
SM7120
SM7500
SM7400
SM6500
SM6020
SM6120

Produk IFM SM8100 yang kami jual adalah barang baru dan bergaransi resmi, silahkan Hubungi Tim marketing kami yang siap membantu untuk info lebih lanjut dan juga untuk mengetahui info harga dan stok dari IFM SM8100 atau produk kami lainnya.

Instrument lainnya

Transmitter IFM Lainnya

Datasheet Katalog IFM SM8100