| Product characteristics |
| Output signal |
analogue signal |
| Measuring range |
| 0…1 bar |
0…1000 mbar |
0…14.5 psi |
0…100 kPa |
|
| Process connection |
threaded connection G 1/4 internal thread |
| Application |
| Special feature |
Gold-plated contacts |
| Application |
for industrial applications |
| Media |
liquids and gases |
| Medium temperature [°C] |
-25…90; (on request: -40…90 °C) |
| Min. bursting pressure |
|
| Pressure rating |
|
| Type of pressure |
relative pressure |
| Electrical data |
| Operating voltage [V] |
9.6…32 DC |
| Min. insulation resistance [MΩ] |
100; (500 V DC) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Inputs / outputs |
| Number of inputs and outputs |
Number of analogue outputs: 1 |
| Outputs |
| Total number of outputs |
1 |
| Output signal |
analogue signal |
| Number of analogue outputs |
1 |
| Analogue current output [mA] |
4…20 |
| Max. load [Ω] |
720; (Ub = 24 V; (Ub – 9,6 V) / 20 mA) |
| Overload protection |
yes |
| Measuring/setting range |
| Measuring range |
| 0…1 bar |
0…1000 mbar |
0…14.5 psi |
0…100 kPa |
|
| Accuracy / deviations |
| Repeatability [% of the span] |
< 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation [% of the span] |
< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
| Long-term stability [% of the span] |
< ± 0,05; (per 6 months) |
| Temperature coefficient zero point [% of the span / 10 K] |
0,1; (0…80 °C) |
| Temperature coefficient span [% of the span / 10 K] |
0,2; (0…80 °C) |
| Response times |
| Step response time analogue output [ms] |
3 |
| Operating conditions |
| Ambient temperature [°C] |
-25…80 |
| Storage temperature [°C] |
-40…100 |
| Protection |
IP 65 |
| Tests / approvals |
| EMC |
| EN 61000-4-2 ESD |
4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated |
30 V/m |
| EN 61000-4-4 Burst |
2 kV |
| EN 61000-4-6 HF conducted |
10 V |
| radiation of interference |
according to the automotive directive 2004/104/EC |
| CISPR 25 |
|
| immunity |
according to the automotive directive 2004/104/EC |
| ISO 11452-2 HF radiated |
100 V/m |
| ISO 7637-2 pulse |
severity level 4 |
|
| Shock resistance |
| DIN EN 60068-2-27 |
50 g (11 ms) |
| DIN EN 61373 |
category 3 |
|
| Vibration resistance |
| DIN EN 60068-2-6 |
20 g (10…2000 Hz) |
| DIN EN 61373 |
category 2 |
|
| MTTF [years] |
506 |
| Pressure Equipment Directive |
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Railway applications |
| DIN EN 50155 / IEC 60571 |
Klasse T3, C1, S1 |
|
| Mechanical data |
| Weight [g] |
221.5 |
| Materials |
stainless steel (1.4404 / 316L); FKM; PA; EPDM/X |
| Materials (wetted parts) |
stainless steel (1.4305 / 303); ceramics; FKM |
| Min. pressure cycles |
100 million |
| Process connection |
threaded connection G 1/4 internal thread |
| Restrictor element integrated |
no (can be retrofitted) |
| anzeigen-bedienelemente |
| Remarks |
| Pack quantity |
1 pcs. |
| Electrical connection |
| Connection |
Connector: 1 x M12; Contacts: gold-plated |