PY2094 IFM Pressure Sensor With Display

Jual IFM PY2094 Pressure Sensor With Display

IFM-PY2094

Jual IFM PY2094 Pressure Sensor With Display

  • Two switching outputs, one of them programmable as IO-Link and one as analogue output
  • Red/green display for clear identification of the acceptable range
  • The process connection can be rotated for optimum alignment
  • With long-term stability thanks to high overload protection
  • Robust design for use in harsh industrial environments
PY2094 Product characteristics
Output signal switching signal; analogue signal; IO-Link; (configurable)
Measuring range
-1…10 bar -14.6…145 psi -0.1…1 MPa
Process connection threaded connection G 1/4 internal thread (DIN EN ISO 1179-2)
Application
Special feature Gold-plated contacts
Measuring element ceramic-capacitive pressure measuring cell
Application for industrial applications
Media liquids and gases
Medium temperature [°C] -25…80
Min. bursting pressure
150 bar 2175 psi 15 MPa
Pressure rating
75 bar 1087 psi 7.5 Mpa
Vacuum resistance [mbar] -1000
Type of pressure relative pressure; vacuum
PY2094 Electrical data
Operating voltage [V] 18…30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA] < 35
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 0.3
Integrated watchdog yes
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 250
Switching frequency DC [Hz] < 500
Number of analogue outputs 1
Analogue current output [mA] 4…20; (scalable 1:5)
Max. load [Ω] 500
Analogue voltage output [V] 0…10; (scalable 1:5)
Min. load resistance [Ω] 2000
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
PY2094 Measuring/setting range
Measuring range
-1…10 bar -14.6…145 psi -0.1…1 MPa
Analogue start point
-1…8 bar -14.6…116 psi -0.1…0.8 MPa
Analogue end point
1…10 bar 14.6…145 psi 0.1…1 MPa
Factory setting / CMPT = 2
Set point SP
-0.94…10 bar -13.6…145 psi -0.094…1 MPa
Reset point rP
-0.98…9.96 bar -14.2…144.4 psi -0.098…0.996 MPa
Min. difference between SP and rP
0.06 bar 0.6 psi 0.006 MPa
In steps of
0.02 bar 0.2 psi 0.002 MPa
Status_B High Resolution / CMPT = 3
Set point SP
-0.94…10 bar -13.6…145 psi -0.094…1 MPa
Reset point rP
-0.98…9.96 bar -14.2…144.4 psi -0.098…0.996 MPa
Min. difference between SP and rP
0.05 bar 0.6 psi 0.005 MPa
In steps of
0.01 bar 0.1 psi 0.001 MPa
PY2094 Accuracy / deviations
Notes on the accuracy / deviation switch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1%
Switch point accuracy [% of the span] < ± 0,4; (Turn down 1:1)
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span] < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span] < ± 0,1; (Turn down 1:1)
Long-term stability [% of the span] < ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero point [% of the span / 10 K] < ± 0,2; (-0…80 °C)
Temperature coefficient span [% of the span / 10 K] < ± 0,2; (-0…80 °C)
Response times
Response time [ms] < 1.5
Delay time programmable dS, dr [s] 0…50
Damping for the switching output dAP [s] 0…4
Damping for the analogue output dAA [s] 0…4
Max. response time analogue output [ms] 3
Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
PY2094 Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
SIO mode yes
Required master port type A; (wenn PIN 2 nicht verbunden: B)
Supported DeviceIDs
Type of operation DeviceID
Factory setting / CMPT = 2 463
Status_B High Resolution / CMPT = 3 974
Note
For further information please see the IODD PDF file under “Downloads”
Factory setting / CMPT = 2
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
Min. process cycle time [ms] 2.3
IO-Link resolution pressure [bar] 0.01
IO-Link process data (cyclical)
function bit length
pressure 14
binary switching information 2
IO-Link functions (acyclical) application specific tag
Status_B High Resolution / CMPT = 3
Profiles Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)
Min. process cycle time [ms] 3
IO-Link resolution pressure [bar] 0.005
IO-Link process data (cyclical)
function bit length
pressure 16
device status 4
binary switching information 2
IO-Link functions (acyclical) application specific tag
Operating conditions
Ambient temperature [°C] -25…80
Storage temperature [°C] -40…100
Protection IP 65; IP 67
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 20 g (10…2000 Hz)
MTTF [years] 138
UL approval
UL Approval no. J012
Pressure Equipment Directive Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
PY2094 Mechanical data
Weight [g] 239
Materials stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts) stainless steel (1.4404 / 316L); Al2O3 (ceramics); FKM
Min. pressure cycles 100 million
Tightening torque [Nm] 25…35; (recommended tightening torque; depends on lubrication, seal and pressure rating)
Process connection threaded connection G 1/4 internal thread (DIN EN ISO 1179-2)
Restrictor element integrated no (can be retrofitted)
Displays / operating elements
Display
Display unit 3 x LED, green (bar, psi, MPa)
switching status 2 x LED, yellow
measured values alphanumeric display, red/green 4-digit
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; Contacts: gold-plated
IFM PY2094 Type Lainnya

PE2093 | PE2592 | PE2591 | PE2596 | PE2593 | PE2099 | PE2091 | PE2599 | PE2096 | PE2092 | PN7670 | PN7699 | PN2698 | PN7696 | PN7697 |  PN2299 | PN7693 | PN2692 | PN2099

PY2099 | PY2209 | PY9964 | PY2033 | PY2068 | PY7001 | PY9294 | PY9292 | PY7002 | PY7000 | PY7003 PY9291 | PY9920 | PY9293 | PY9961 | PN2091 | PN2090

PA3020 | PA3021 | PA3022 | PA3023 | PA3024 | PA3221 | PA3222 | PA3223 | PA3224 | PA3226

IFM PY2094 Seri Lainnya

PN7099 | PN2694 | PN2594 | PN3594 | PN2098 | PN7592 | PN2293 | PN2271 | PN3129 | PN7593 | PN3571 | PN2292 | PN7572 | PN7271 | PN7270 | PN7160 | PN2270 | PN2693 | PN7292 | PN3160 | PN7097 |

PN7570 | PN7694 | PN2593 | PN2571 | PN2097 | PN3097 | PN2298 | PN2096 | PN3570 | PN7293 | PN3096 PN3593 | PN2570 | PN2296 | PN7299 | PN7370 | PN2592 | PN2598 | PN2599 | PN2699 |PN2671 |