FX2N-32CCL Mitsubishi Electric

Jual FX2N-32CCL | Mitsubishi Electric

FX2N-32CCL

PLC Mitsubishi Electric FX2N-32CCL 

Programmable logic controller (PLC) atau programmable controller

Pengontrol logika terprogram (PLC) adalah sistem kontrol yang menggunakan operasi elektronik. Prosedur penyimpanannya yang mudah, prinsip perluasan yang praktis, fungsi kontrol sekuensial / posisi, penghitungan waktu dan kontrol input / output diterapkan secara luas pada bidang kontrol otomasi industri.

Industri aplikasi utama PLC: industri mesin tekstil mesin tekstil, industri mesin angkat, industri elevator, industri metalurgi, industri tenaga listrik, industri perminyakan dan petrokimia, industri kota, industri kimia, industri konstruksi bangunan, industri bahan bangunan, industri peralatan mesin, mesin plastik, mesin karet, peralatan khusus elektronik, industri otomotif, dll.

FX2N-32CCL Mitsubishi Electric Description :

  • Manufacturer : Mitsubishi Electric
  • FX2N-32CCL
  • CC-Link system interface block (remote device station)
  • CC-Link version : Ver.1.00
  • FX2N-32CCL Station type : Remote device station
  • Insulation method : The network bus and the internal power supply are photocoupler isolated
  • Transmission speed : 156 kbps / 625 kbps / 2.5 Mbps / 5 Mbps / 10 Mbps selectable (set with rotary switch)
  • FX2N-32CCL Station number : 1 to 64 stations (set with rotary switch)
  • Number of occupied stations : 1 to 4 stations (set with rotary switch)
  • Maximum cable total extension (maximum transmission distance) : Different according to transmission speed up to 1200 m
  • Number of remote I / O points : The number of remote I / O points per station is 32 input points and 32 output points. However, the upper 16 points of the last station are occupied by the CC-Link system as the system area.
  • Remote register point number : The number of remote registers per station is 4 RW write areas, 4 RW read areas.
  • Number of links per station : Remote input / output 32 points / 32 points (RX / RY) However, the upper 16 points of the last station are occupied by the CC-Link system as a system area. Remote register (RWw) 4 points (Master station ? Remote device station) Remote register (RWr) 4 points (Remote device station ? Master station)
  • FX2N-32CCL Communication method : Polling method
  • Synchronization method : Frame synchronization method
  • FX2N-32CCL Coding scheme : NRZI system
  • Transmission path format : Bus (RS-485)
  • Transmission format : HDLC compliant
  • FX2N-32CCL Error control method : CRC (X 16 + X 12 + X 5 + 1)
  • Connection cable : CC-Link dedicated cable, CC-Link exclusive high-performance cable CC-Link exclusive cable and CC-Link exclusive high-performance cable can not be mixed.
  • Communicate with the sequencer : Performing via buffer memory with FROM / TO instruction
  • FX2N-32CCL Display (LED) : RD, SD, L RUN, L ERR, POWER
  • FX2N-32CCL Number of occupied I / O points : 8 points (It can count either input or output)
  • Application sequencer : FX1N, FX3G, FX2N, FX3U, FX1NC, FX3GC, FX2NC, FX3UCFX2NC – CNV – IF is required for connection to FX1NC and FX2NC. To connect to FX3GC, FX3UC, FX2NC – CNV – IF or FX3UC – 1PS – 5V is required.
  • FX2N-32CCL mass : 0.2 Kg
  • FX2N-32CCL Power supply : DC 5 V internal power supply: Power is supplied from the sequencer via extension cable. DC 24 V external power supply (24 VDC ± 10%): Power is supplied from the external terminal block.
  • Current consumption : DC 5 V internal power supply: 130 mA DC 24 V external power supply: 50 mA
  • FX2N-32CCL Ambient temperature : 0 to 55 ° C. … Operating -25 to 75 ° C. ….. Save
  • Relative humidity : 5 to 95% RH (noncondensing)…. in operation
  • Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total)
  • Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total)
  • Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total)
  • Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total)
  • FX2N-32CCL Impact resistance : 147 m / s 2 , working time 11 ms, three times in X, Y, Z directions with a sine half-wave pulse
  • Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 µs, rising 1 ns, with noise si
  • tor with period of 30 to 100 Hz
  • Withstand voltage : Between external terminals and ground terminal: 500 VAC for 1 minute
  • Insulation resistance : Between external terminal and ground terminal: 500 MV DC 500 MO or more with insulation resistance meter
  • ground : Class D grounding (grounding resistance: 100 O or less)Grounding should be dedicated ground or common ground.
  • Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious
  • Use altitude : Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.