SU7000 IFM Product characteristics |
Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
Measuring range |
|
Process connection |
threaded connection G 3/4 flat seal |
Application |
Special feature |
Gold-plated contacts |
Application |
totaliser function; for industrial applications |
Installation |
connection to pipe by means of an adapter |
Media |
water; glycol solutions; coolants; oil |
Note on media |
low-viscosity oils with viscosity: 7…40 mm²/s (40 °C) |
high-viscosity oils with viscosity: 30…68 mm²/s (40 °C) |
|
Medium temperature [°C] |
-10…80 |
Pressure rating [bar] |
16 |
Pressure rating [Mpa] |
1.6 |
SU7000 IFM Electrical data |
Operating voltage [V] |
19…30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA] |
100 |
Min. insulation resistance [MΩ] |
100; (500 V DC) |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
10 |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
Inputs |
Inputs |
counter reset |
Outputs |
Total number of outputs |
2 |
Output signal |
switching signal; analogue signal; pulse signal; (configurable) |
Electrical design |
PNP/NPN |
Number of digital outputs |
2 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] |
2 |
Permanent current rating of switching output DC [mA] |
250; (per output) |
Number of analogue outputs |
1 |
Analogue current output [mA] |
4…20; (scalable) |
Max. load [Ω] |
500 |
Analogue voltage output [V] |
0…10; (scalable) |
Min. load resistance [Ω] |
2000 |
Pulse output |
flow rate meter |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
SU7000 IFM Measuring/setting range |
Measuring range |
|
Display range |
|
Resolution |
|
Set point SP |
0.1…50 l/min |
0.005…3 m³/h |
|
Reset point rP |
0…49.9 l/min |
0…2.995 m³/h |
|
Analogue start point ASP |
|
Analogue end point AEP |
|
Max. flow rate |
|
In steps of |
|
Volumetric flow quantity monitoring |
Pulse value |
0.1 l…1 000 000 m³ |
Pulse length [s] |
0,05…2 |
SU7000 IFM Temperature monitoring |
Measuring range [°C] |
-10…80 |
Resolution [°C] |
0.2 |
Set point SP [°C] |
-9.8…80 |
Reset point rP [°C] |
-10…79.8 |
Analogue start point [°C] |
-10…62 |
Analogue end point [°C] |
8…80 |
In steps of [°C] |
0.2 |
Accuracy / deviations |
Flow monitoring |
Accuracy (in the measuring range) |
< ± (3 % MW + 0,2 % MEW) / < ± (5 % MW + 0,5 % MEW); (water; glycol: 35%; oil: viscosity 68 mm²/s at 40 °C) |
Repeatability |
0,1 l/min; 6 l/h; 0,006 m³/h |
Temperature monitoring |
Accuracy [K] |
± 3 (Q > 1 l/min) |
Response times |
SU7000 IFM Flow monitoring |
Response time [s] |
0.25; (dAP = 0) |
Delay time programmable dS, dr [s] |
0…50 |
Damping for the switching output dAP [s] |
0…1 |
Temperature monitoring |
Dynamic response T05 / T09 [s] |
T09 = 70 (Q > 5 l/min); (water) |
Software / programming |
Parameter setting options |
Flow monitoring; quantity meter; Preset counter; Temperature monitoring |
Operating conditions |
Ambient temperature [°C] |
-10…60 |
Storage temperature [°C] |
-25…80 |
Protection |
IP 67 |
Tests / approvals |
EMC |
EN 61000-4-2 ESD |
4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated |
10 V/m |
EN 61000-4-4 Burst |
2 kV |
EN 61000-4-5 Surge |
0,5 kV |
EN 61000-4-6 HF conducted |
10 V |
|
CPA approval |
model number |
001US |
accuracy class |
5 |
maximum permissible measurement deviation |
– |
Q (min) |
0,0162 m³/h |
Q (t) |
0,312 m³/h |
Q (max) |
3 m³/h |
|
Shock resistance |
DIN IEC 68-2-27 |
20 g (11 ms) |
|
Vibration resistance |
DIN IEC 68-2-6 |
5 g (10…2000 Hz) |
|
MTTF [years] |
175 |
Pressure Equipment Directive |
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
SU7000 IFM Mechanical data |
Weight [g] |
1551.5 |
Materials |
housing: AlMgSi0,5 anodised; Sealing: FKM; PA 6.6; cover film: PA |
Materials (wetted parts) |
stainless steel (1.4404 / 316L); FKM; PES; Centellen 200 |
Process connection |
threaded connection G 3/4 flat seal |
SU7000 IFM Displays / operating elements |
Display |
Display unit |
6 x LED, green (l/min, m³/h, l, m³, 10³, °C) |
switching status |
2 x LED, yellow |
measured values |
alphanumeric display, 4-digit |
programming |
alphanumeric display, 4-digit |
|
SU7000 IFM Accessories |
Items supplied |
|
Accessories (optional) |
adapter for pipe: 1 x R1/2, stainless steel, E40178 |
adapter for pipe: 1 x R1/2, brass, E40151 |
|
Remarks |
Remarks |
MW = measured value |
MEW = Final value of the measuring range |
sealing: only with supplied Centellen seals |
|
Pack quantity |
1 pcs. |
SU7000 IFM Electrical connection |
Connection |
Connector: 1 x M12; Moulded body: brass, Optalloy-plated; Contacts: gold-plated |