SU7000 IFM Ultrasonic flow meter

SU7000 IFM Ultrasonic flow meter

SU7000

Jual SU7000 IFM Ultrasonic flow meter

SU7000 IFM Ultrasonic flow meter Benefit : 

  • Precise measurement of flow, consumption and medium temperature
  • Suitable for water, oils and glycol solutions
  • For installation in pipes
  • With switching output, analogue output and pulse output
  • Clearly visible 4-digit LED display
SU7000 IFM Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
0…50 l/min 0…3 m³/h
Process connection threaded connection G 3/4 flat seal
Application
Special feature Gold-plated contacts
Application totaliser function; for industrial applications
Installation connection to pipe by means of an adapter
Media water; glycol solutions; coolants; oil
Note on media
low-viscosity oils with viscosity: 7…40 mm²/s (40 °C)
high-viscosity oils with viscosity: 30…68 mm²/s (40 °C)
Medium temperature [°C] -10…80
Pressure rating [bar] 16
Pressure rating [Mpa] 1.6
SU7000 IFM Electrical data
Operating voltage [V] 19…30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA] 100
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 10
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputs counter reset
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; pulse signal; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 250; (per output)
Number of analogue outputs 1
Analogue current output [mA] 4…20; (scalable)
Max. load [Ω] 500
Analogue voltage output [V] 0…10; (scalable)
Min. load resistance [Ω] 2000
Pulse output flow rate meter
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
SU7000 IFM Measuring/setting range
Measuring range
0…50 l/min 0…3 m³/h
Display range
0…60 l/min 0…3.6 m³/h
Resolution
0.1 l/min 0.005 m³/h
Set point SP
0.1…50 l/min 0.005…3 m³/h
Reset point rP
0…49.9 l/min 0…2.995 m³/h
Analogue start point ASP
0…40 l/min 0…2.4 m³/h
Analogue end point AEP
10…50 l/min 0.6…3 m³/h
Max. flow rate
60 l/min 3.6 m³/h
In steps of
0.1 l/min 0.005 m³/h
Volumetric flow quantity monitoring
Pulse value 0.1 l…1 000 000 m³
Pulse length [s] 0,05…2
SU7000 IFM Temperature monitoring
Measuring range [°C] -10…80
Resolution [°C] 0.2
Set point SP [°C] -9.8…80
Reset point rP [°C] -10…79.8
Analogue start point [°C] -10…62
Analogue end point [°C] 8…80
In steps of [°C] 0.2
Accuracy / deviations
Flow monitoring
Accuracy (in the measuring range) < ± (3 % MW + 0,2 % MEW) / < ± (5 % MW + 0,5 % MEW); (water; glycol: 35%; oil: viscosity 68 mm²/s at 40 °C)
Repeatability 0,1 l/min; 6 l/h; 0,006 m³/h
Temperature monitoring
Accuracy [K] ± 3 (Q > 1 l/min)
Response times
SU7000 IFM Flow monitoring
Response time [s] 0.25; (dAP = 0)
Delay time programmable dS, dr [s] 0…50
Damping for the switching output dAP [s] 0…1
Temperature monitoring
Dynamic response T05 / T09 [s] T09 = 70 (Q > 5 l/min); (water)
Software / programming
Parameter setting options Flow monitoring; quantity meter; Preset counter; Temperature monitoring
Operating conditions
Ambient temperature [°C] -10…60
Storage temperature [°C] -25…80
Protection IP 67
Tests / approvals
EMC
EN 61000-4-2 ESD 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated 10 V/m
EN 61000-4-4 Burst 2 kV
EN 61000-4-5 Surge 0,5 kV
EN 61000-4-6 HF conducted 10 V
CPA approval
model number 001US
accuracy class 5
maximum permissible measurement deviation
Q (min) 0,0162 m³/h
Q (t) 0,312 m³/h
Q (max) 3 m³/h
Shock resistance
DIN IEC 68-2-27 20 g (11 ms)
Vibration resistance
DIN IEC 68-2-6 5 g (10…2000 Hz)
MTTF [years] 175
Pressure Equipment Directive Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
SU7000 IFM Mechanical data
Weight [g] 1551.5
Materials housing: AlMgSi0,5 anodised; Sealing: FKM; PA 6.6; cover film: PA
Materials (wetted parts) stainless steel (1.4404 / 316L); FKM; PES; Centellen 200
Process connection threaded connection G 3/4 flat seal
SU7000 IFM Displays / operating elements
Display
Display unit 6 x LED, green (l/min, m³/h, l, m³, 10³, °C)
switching status 2 x LED, yellow
measured values alphanumeric display, 4-digit
programming alphanumeric display, 4-digit
SU7000 IFM Accessories
Items supplied
sealings: 2, Centellen
Accessories (optional)
adapter for pipe: 1 x R1/2, stainless steel, E40178
adapter for pipe: 1 x R1/2, brass, E40151
Remarks
Remarks
MW = measured value
MEW = Final value of the measuring range
sealing: only with supplied Centellen seals
Pack quantity 1 pcs.
SU7000 IFM Electrical connection
Connection Connector: 1 x M12; Moulded body: brass, Optalloy-plated; Contacts: gold-plated

SU7000 IFM Ultrasonic flow meter & Other Series :

PA3020 | PA3021 | PA3022 | PA3023 | PA3024 | PA3026 | PA3027 | PA3029 | PA3060 | PA3220 | PA3221 | PA3222 | PA3223 | PA3224 | PA3226

IFM PA3223 & PN Series

PN3094 | PN7070 | PN3071 | PN2071 | PN2294 | PN7294 | PN3092 | pN7096 | PN2092 | PN2093 | PN7571 | PN7594 | PN3093 | PN3070 | PN2070 | PN7099 | PN2694 | PN2594 | PN3594 | PN2098 | PN7592 | PN2293 | PN2271 | PN3129 |
PN7593 | PN3571 | PN2292 | PN7572 | PN7271 | PN7270 | PN7160 | PN2270 | PN2693 | PN7292 | PN3160 | PN7097 |

PN7570 | PN7694 | PN2593 | PN2571 | PN2097 | PN3097 | PN2298 | PN2096 | PN3570 | PN7293 | PN3096 | PN3593 | PN2570 | PN2296 | PN7299 | PN7370 | PN2592 | PN2598 | PN2599 | PN2699 |PN2671 | PN7072 | PN2160 | PN2569 |

PN7596 | PN7599 | PN3529 | PN7671 |PN7296 | PN3592 | PN2297 | PN2670 | PN2169 | PN2560 | PN2696 | PN2697 | PN7392 | PN2597 | PN7597 | PN7297 | PE2094 | PN2596 | PN3597 | PE2594 | PN7560 | PN3560 | PN3596 | PN7692 |

SU7000 IFM & PE Series

PE2093 | PE2592 | PE2591 | PE2596 | PE2593 | PE2099 | PE2091 | PE2599 | PE2096 | PE2092 | PN7670 | PN7699 |
PN2698 | PN7696 | PN7697 | PN2299 | PN7693 | PN2692 | PN2099 | PY2099 | PY2209 | PY9964 | PY2033 | PY2068 | PY7001 | PY9294 | PY9292 | PY7002 | PY7000 | PY7003 | PY9291 | PY9920 | PY9293 | PY9961 | PN2091 | PN2090 |

Instrument lainnya

Transmitter IFM Lainnya

Datasheet Katalog IFM SU7000